Home :: Health and Fitness :: BP Apparatus Aneroid (Sphygmomanometer & Stethoscope)

BP Apparatus Aneroid (Sphygmomanometer & Stethoscope)

BP Apparatus Aneroid (Sphygmomanometer & Stethoscope)
BRAND NEW ANEROID SPHYGMOTER WITH STETHOSCOPE


Aneroid manometer, with single head stethoscope

Measure scope: 0-300mmHg

Accuracy: +/-3mmHg

Sub-division: 2mmHg

023 Nylon cuff with D-ring 51*14cm

053.2 Bladder, 22*12cm

069 Leatheroid bag



FOR HOSPITAL, HOME, OFFICE, SCHOOL AND TRAVEL USE

COMES IN ZIPPER CASE AND GIFT BOX
WITH INSTRUCTIONS



What is Blood Pressure?

Blood pressure is a measurement of the pressure of the blood flowing against the walls of the arteries. Arterial blood pressure is constantly changing during the course of the cardiac cycle. The highest pressure in the cycle is called the systolic blood pressure; the lowest is thediastolic blood pressure; both readings are necessary to enable you to evaluate the status of your blood pressure. Many factors such as physcial activity, anxiety, or the time of day, can influence your blood pressure. Blood pressure is typically low in the morning but high from afternoon to evening. It is lower in the summer but higher in the winter.

What is normal blood pressure?


Blood pressure varies from individual to individual and is dependant upon a number of factors, such as age and weight, physical condition, or gender. The classic normal reading for an adult between the ages of 18 and 45 is 120/80. Remember, only your physician is qualified to determine whether the readings you obtain are normal for you.

How to measure the blood pressure?


1. Relax yourself and adjust to a proper position

It is very important that the person whose blood pressure is being taken is relaxed and sitting comfortably.
Keep arm being measured at heart level. Arm extended but not too tense or stiff. Rest arm on a flat surface, such as a desk with the left palm facing upwards. Keep arm being measured still.
2. How to put on the velcro cuffs and chestpiece


Place the cuff 2-3cm above the bend of the elbow and the naked left upper arm; Close the cuff by means of the velcro closure. Cuff should be snug, but not too tight, one or two fingers should fit between the cuff and arm. Never place cuff over article of clothing
For cuff with metal D-shaped ring, pull the free end of the cuff through the D-ring and close the cuff by means of the velcro closure.
In units intended for home use, the diaphragm of the chestpiece of the stethoscope integrated into the cuff must be placed above the brachial artery
3. Inflating the cuff


Close the air valve on the bulb by turning the screw clockwise. Do not over tighten
Squeeze the inflation bulb with the hand you used to at a steady rate until the needle on the guage points 30mmHg above your normal upper systolic pressure value. If you dont know it, inflate just to 200mmHg
4. Systolic blood pressure reading - Upper value


Slowly open air valve by turning screw counter clockwise and hold stethoscope chestpiece over brachial artery. Proper deflation rate is vital for an accurate reading so you should practice and master a recommended deflation rate of 2-3mmHg per second or a drop one or two marks on the pressure guage each heartbeat. You should not keep the cuff inflated any longer than necessary. As the cuff begins to deflate, you must listen carefully with the stethoscope. Notr the reading on the guage as soon as you hear a faint, rhythmic tapping or thumping sounds.This is the systolic-upper-blood pressure reading. Listen carefully and familiarise yourself with pulse sound. Once familiar you should check this procedure with your physician.
5. Diastolic blood pressure reading- Lower value


Allow the pressure to continue dropping at the same deflation rate. When your diastolic-lower-pressure value reeached, the thumping sound stops.
Deflate the cuff valve. Remove the cuff from arm.
6. Record your readings

Repeat the measurement one or two more times. Do not forget your readings and the time of the day measurement is made immediately after you finish measuring. A convenient time is first thing in the morning, or just before evening meals.Remember that your phsicia is the only person qualified to analyse your blood pressure.
Maintenance

with proper care and maintenance, your blood pressure kit will provide years of satisfactory surface. The basic rules:

Do not drop jar
Never inflate beyond 300mmHg
Never expose the cuffs to intense solar radiation
Never touch the cuff fabric or parts with a sharp instrument, since this this could cause damage
Always deflate cuff completely before storage
Do not dismantle manometer under any circumstance
Store complete instrument in storage case provided, to keep the chestpiece and all the other parts clean
Storage temperate condition: -20°C to 70°C at a relative air humidity of 85% (non-condensing)
Wipe off the monometer and bulb with a damp cloth. Sterilisation is not necessary, since the parts do not come into direct contact with the patient's body.
Remove the bladder first, and wipe the velcro, bladder, and tubes with a damp cloth. The cuff can be washed with soap and cold water like all the other cuffs, but you must rinse the cuffs with clear water afterwards and let them air dry.
MEDICAL RELIEF WORKERS / AGENCIES
CONTACT US FOR BULK DISCOUNTS
(Authentication Required)
18%
SKU Spygmo
Market price: AUD 34.00
Our price: AUD 28.00
Quantity
: *
: *
: *
 
XFT TENS Machines Replacement Acupuncture Pen for TENS Machine 3 Skipping Ropes (pink)
AUD 38.00
AUD 8.40
AUD 13.70
 
US Air Force One Large Plane Model 45 cm Toy Train Engine Set Dragtor Drag Racing Tractor
AUD 98.00
AUD 39.00
AUD 86.00
 
Model Retro Car Collection with Garage and Caravan Camera Lens Music/Calendar/Alarm Clock 2x TIN TOY POP POP PUTT PUTT CANDLE POWERED BOATS INCLUDES 2 CANDLES
AUD 68.00
AUD 18.20
AUD 22.00